OS GSO ISO/IEC TR 14543-4:2014
ISO/IEC TR 14543-4:2002
Omani Standard
Current Edition
·
Approved on
25 December 2014
Information technology - Home electronic system (HES) architecture - Part 4: Home and building automation in a mixed-use building
OS GSO ISO/IEC TR 14543-4:2014 Files
English
18 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
OS GSO ISO/IEC TR 14543-4:2014 Scope
This part of ISO/IEC 14543 presents methods for overall building management of the home electronic system (HES) architecture. The interaction of building and home control systems requires a demarcation between building manager versus tenant responsibilities. A method for implementing agreements between building managers and tenants regarding user access to and control of applications via a firewall is specified.
This technical report augments series ISO/IEC 14543, the architecture of HES (Home Electronic System), in order to accommodate both home and building automation in a mixed use building. Both systems may coexist in a building with shops, offices and apartments. Some systems are applicable to the whole building versus the systems which are applicable to individual apartments and offices only. In some cases these systems need to interact.
This technical report proposes a logical model for linking building and home control systems even if the two use different physical arrangements of components. The basic recommendations are:
• allow for distinct and separate building and home automation control systems, possibly supplied by different manufacturers;
• define clear points of connection between building and home control systems;
• limit the number of points of connection between building and home control systems,preferably to one per home system;
• accommodate systems that provide building tenants with user control of local systems. This favors an architecture where products can be designed for the user to override control decisions within parameters agreed with building management. Such actions are exercised by the building automation system and affect local systems. This enhances user safety and user privacy;
• provide seamless links between systems that are based on different architectures, that incorporate different communications protocols, and that may be purchased from different manufacturers.
Best Sellers From Electrical Sector
GSO 2530:2016
Gulf Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 2530:2016
GSO 2530:2016
Omani Standard
Energy Labelling And Minimum Energy Performance Requirements For Air-Conditioners
OS GSO 34:2007
GSO 34:2007
Omani Standard
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
GSO 34:2007
Gulf Technical Regulation
LEAD-ACID STARTER BATTERIES USED FOR
MOTOR VEHICLES AND INTERNAL
COMBUSTION ENGINES
Recently Published from Electrical Sector
GSO IEC PAS 63629:2026
IEC PAS 63629:2025
Gulf Standard
PSR – Specific rules for luminaires
GSO IEC 60704-2-3:2026
IEC 60704-2-3:2025
Gulf Standard
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-3: Particular requirements for dishwashers
GSO IEC 60270:2026
IEC 60270:2025
Gulf Standard
High-voltage test techniques – Charge-based measurement of partial discharges
GSO IEC 60809:2026
IEC 60809:2021
Gulf Standard
Lamps and light sources for road vehicles - Dimensional, electrical and luminous requirements